Your Location: Home > Service > Fault

Common faults-vacuum pump maintenance-working principle of vacuum pump

    (一) Motor does not rotate

    1、Not connected to the power supply - connected to the power supply

    2、The motor does not work - check the motor wiring or replace the motor

    3、The fan head is damaged - repair the fan or replace it

    4、There is a foreign object stuck in the fan - remove the foreign object

    (二) Increased noise

    1、Bearing dry lubrication - add bearing grease

    2、Bearing damage - replace the bearing

    3、Impeller wear - replace impeller or pump head

    4、Fasteners are loose or falling off - tighten fasteners

    5、There is foreign matter in the fan - remove the foreign matter or replace the pump head

    (三) Increased vibration

    1、Bearing damage - replace the bearing

    2、Impeller is unbalanced - remove foreign matter in the impeller or correct dynamic and static balance

    3、Spindle deformation - replace the spindle or pump head

    4、The working status enters the turbulent earthquake zone - adjust the working status to avoid the turbulent earthquake zone

    5、The air inlet and outlet inlet filters are clogged - clean the filters

    (四) temperature rise

    1、The air inlet temperature is too high - reduce the air inlet temperature

    2、Bearing dry lubrication - add bearing grease

    3、The fan efficiency is reduced - clear the dust from the blade path or replace the pump head

    4、Change of working status - adjust working status

    5、Increased ambient temperature - increase ambient ventilation and heat dissipation

    (五) pressure decrease

    1、The pump head speed is reduced - the power supply voltage is low or the motor is faulty

    2、Increased pipe network resistance—reduce pipe network resistance

    3、Change of working status - adjust working status

    4、Motor rotation reversed - motor rewired

    (六) flow decreases

    1、The inlet and outlet air filters are clogged - clean the filters

    2、The pump head speed is reduced - the power supply voltage is low or the motor is faulty

    3、Increased pipe network resistance—reduce pipe network resistance

    4、Increase working status - adjust working status

    5、Motor rotation reversed - motor rewired